Test Report Number : TWNC00149239
Applicant: tesa SE Date : Mar 05, 2010
Quickbornstrasse 24
20253 Hamburg Germany
Sample Description:
One (1) group of submitted samples said to be : Sample Description : Double-sided tape Style / Item No. : tesa4983,tesa4972,tesa4980,tesa4928 Date Sample Received : Feb 26, 2010 Date Test Started : Mar 01, 2010
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services Taiwan Limited
K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory.
Page 1 Of 5
Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114台北市內湖區瑞光路423號8樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number :TWNC00149239
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content
Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE)
Remarks:ppm = parts per million based on weight of tested sample = mg/kg ND = Not Detected
Date Sample Received : Feb 26, 2010 Testing Period : Mar 01, 2010 To Mar 05, 2010
Result (ppm) Submitted Samples (Release Liners Were Excluded) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Responsibility Of Chemist :Irene Chiou / Kevin Liu / Cathy Chen
Page 2 Of 5
Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114台北市內湖區瑞光路423號8樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number :TWNC00149239
Test Conducted
(Ⅱ) RoHS Requirement:
Restricted Substances Limits Cadmium (Cd) Content 0.01% (100ppm) Lead (Pb) Content 0.1% (1000ppm) Mercury (Hg) Content 0.1% (1000ppm) 6+Chromium VI (Cr) Content 0.1% (1000ppm) Polybrominated Biphenyls (PBBs) 0.1% (1000ppm) Polybrominated Diphenyl Ehters (PBDEs) 0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material.
(Ⅲ) Test Method: Method MDL Testing Item Testing With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by
Cadmium (Cd) content microwave digestion until the tested 2 ppm
samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by
Lead (Pb) content microwave digestion until the tested 2 ppm
samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave
Mercury (Hg) content digestion until the tested samples 2 ppm
are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 6+
Chromium VI (Cr) 1.0:2008 in annex C, by alkaline 1 ppm content digestion and determined by UV-Vis
spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent
Polybrominated
extraction and determined by GC-MSD 5 ppm Biphenyls (PBBs)
and further HPLC confirmation when necessary. With reference to IEC 62321 edition Polybrominated 1.0:2008 in annex A, by solvent Diphenyl Ethers extraction and determined by GC-MSD 5 ppm (PBDEs) and further HPLC confirmation when
necessary.
Remark: MDL = Quantitation Limit Of Testing Method
Page 3 Of 5
Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114台北市內湖區瑞光路423號8樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number :TWNC00149239
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Standard: IEC 62321 edition 1.0:2008
End Of Report Page 4 Of 5
Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114台北市內湖區瑞光路423號8樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number :TWNC00149239
Test Conducted
Photo
Page 5 Of 5
Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114台北市內湖區瑞光路423號8樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
因篇幅问题不能全部显示,请点此查看更多更全内容
Copyright © 2019- yrrf.cn 版权所有 赣ICP备2024042794号-2
违法及侵权请联系:TEL:199 1889 7713 E-MAIL:2724546146@qq.com
本站由北京市万商天勤律师事务所王兴未律师提供法律服务