Chapter 12 Linear machine Basics
The Linear Motor Concept
The idea is simple enough. Take a conventional rotary servo motor and unwrap it. So now what was the stator is now a forcer and the rotor becomes a coil or magnet rail. With this design, the load is connected directly to the motor. Direct linear motion is achieved without any rotary to linear transmission devices.
Linear motor technology is not new. Step motor and brushed linear motor products have been available for quite some time. Brushless technology is becoming increasingly popular as applications take advantage of its technology.
Brushed linear had the coils in the linear rail and the magnets were in the forcer. Commutation was accomplished by a linear commutation bar that ran the length of the motor with brushes in the forcer. This method was both expensive and limited. The cost of winding feet after feet of linear motor rail was time and material intensive. High speed operation was limited due to commutation bar and brushes.
Linear step motors have both windings and permanent magnets within the forcer. It travels along a rail having an etched tooth structure. While maintaining the step motor advantage of open loop operation, the technology does have some limitation in speed and available force.
With brushless servo motor technology, and the supporting electronics to drive them, the above limitations have been eliminated. The forcer is now a set of windings while the stator is a rail of magnets. Commutation is done electronically either by Halleffect sensors or sinusoidal. Hall effect sensors located within the forcer are activated by the magnets on the rail. The amplifier translates these signals into appropriate phase currents. Sine commutation is accomplished using the linear encoder signals back to the controller. A common technique is the use of Hall-effect initially and then switching to
sinusoidal commutation. In any case, the speed of commutation is not the limiting factor. The force generated by the same size motor is greater than brush motor technology due to improved magnet materials.
Linear Motor Benefits:
High speeds, The maximum speed of a linear motor is limited only by the bus voltage and the speed of the control electronics. Typical speeds for linear motors are 3 meters per second with 1 micron resolution and over 5 meters per second, 200ips, with coarser resolution.
High Precision: The accuracy, resolution, and repeatability of a linear motor driven device is controlled by the feed back device. With the wide range of linear feedback devices available, resolution and accuracy are primarily limited to budget and control system bandwidth.
Fast Response: The response rate of a linear motor driven device can be over 100 times that of a mechanical transmission. This means faster accelerations and settling times, thus more throughput.
Stiffness: Because there is no mechanical linkage, increasing the stiffness is simply a matter of gain and current. The spring rate of a linear motor driven system can be many times that of a ball screw driven device. However it must be noted that this is limited by the motors peak force, the current available and the resolution of the feedback.
Zero Backlash: Without mechanical transmission components, there is no backlash. Resolution considerations do exist. That is the linear motor must be displaced by 1 feedback count before it will begin to correct its position.
Maintenance Free Operation: Because the linear motors of today have no contacting parts there is no wear.
What are the Down Sides?
·
Cost: Linear Motors are expensive. This is due to the relative low volume produced, and the price of magnets. Since most linear motor designs mount rare earth magnets to the length of the rail, and the cost of these magnets is high, long travel motors become expensive. However as the popularity of linear motors continues, volume will rise and cost will decline. This process has begun. Linear feedback must also be considered in the cost of using a linear motor. Rotary motor feedback, (encoder or resolver) is relatively inexpensive (<$100 list) and is not “length” dependent. Linear motors typically require a linear encoder for feedback. These devices are many times more expensive than their rotary counterparts. A 100 mm travel linear encoder list in the neighborhood of $500, and cost increases with length. With newer reflective type encoder technologies, the manufacturing costs are declining, and with continued increases in the use of these encoders, prices will follow. Most importantly, if system accuracy requires linear encoder feedback, the cost differential between linear and rotary technology is greatly reduced.
Higher Bandwidth Drives and Controls: Since there is no mechanical reduction between the motor and the load, servo response, bandwidth, must be faster. This includes higher encoder bandwidth and servo update rates.
Force Per Package Size: Linear motors are not compact force generators compared to a rotary motor with a transmission offering mechanical advantage. For example to produce even 65 N (15 lb) of continuous force, a linear motor's cross section is approximately 50 mm x 40 mm (2”x 1.5”). Compare this to the cross section of a 10 mm (3/8”) diameter ball screw which produces 100 lb. of thrust and one can see that linear motors are not brute force devices. · Heating: In most linear motor applications, the forcer is attached to the load. Any I2R losses are then directly coupled to the load. If an application is sensitive to heat, thermal management techniques need to be applied. Air and water cooling options are popular and common. · No (minimal) Friction: This may not sound like a problem, but it certainly can be. For instance, a linear motor is traveling at 3 meters/second (120 ips) and loses power.
Without some resistance in the system, it does not take long before the motor reaches the end of stroke and mechanical stops.
12.1 概 述
直线电机是近年来国内外积极研究发展的新型电机之一。它是一种不需要中间转换装置,而能直接作直线运动的电动机械。过去,在各种工程技术中需要直线运动时,一般是用旋转电机通过曲柄连杆或蜗轮蜗杆等传动机构来获得的。 但是,这种传动形式往往会带来结构复杂,重量重,体积大,啮合精度差且工作不可靠等缺点。
·
齿轮齿条
曲柄连杆机构
近十几年来,科学技术的发展推动了直线电机的研究和生产,目前在交通运输、机械工业和仪器仪表工业中,直线电机已得到推广和应用。在自动控制系统中,采用直线电机作为驱动、指示和信号元件也更加广泛,例如在快速记录仪中,伺服电动机改用直线电机后, 可以提高仪器的精度和频带宽度; 在雷达系统中, 用直线自整角机代替电位器进行直线测量可提高精度,简化结构;在电磁流速计中,可用直线测速机来量测导电液体在磁场中的流速;另外,在录音磁头和各种记录装置中,也常用直线电机传动。
与旋转电机传动相比,直线电机传动主要具有下列优点:
(1) 直线电机由于不需要中间传动机械,因而使整个机械得到简化,提高了精度,减少了振动和噪音;
(2) 快速响应:用直线电机驱动时,由于不存在中间传动机构的惯量和阻力矩的影响,因而加速和减速时间短,可实现快速启动和正反向运行;
(3) 仪表用的直线电机,可以省去电刷和换向器等易损零件,提高可靠性, 延长使用寿命;
直线电机有多种型式,原则上对于每一种旋转电机都有其相应的直线电机。 一般,按照工作原理来区分,可分为直线感应电机、直线直流电机和直线同步电机(包括直线步进电机)三种。在伺服系统中,和传统元件相应,也可制成直线运动形式的信号和执行元件。
12.2 直线感应电动机
12.2.1 主要类型和结构
直线感应电机主要有两种型式,即平板型和管型。平板型电机可以看作是由普通的旋转感应(异步)电动机直接演变而来的。图12 - 1(a)表示一台旋转的感
应电动机,设想将它沿径向剖开,并将定、转子圆周展成直线,如图12 - 1(b), 这就得到了最简单的平板型直线感应电机。
由定子演变而来的一侧称作初级,由转子演变而来的一侧称作次级。直线电机的运动方式可以是固定初级,让次级运动,此称为动次级;相反,也可以固定次级而让初级运动,则称为动初级。
图 12 - 1 直线电机的形成
(a) 旋转电机; (b) 直线电机
图12 – 7 行波磁场
vs2f τ为极距, f为电源频率。 svsv v(1s)vs2f(1s) vs
图 12 - 2 平板型直线电动机 (a) 短初级; (b) 短次级
图 12 - 4 管型直线感应电机的形成
(a) 平板型; (b) 管型
图12 - 5 直线感应电机的线圈 图12 - 6 两相管型直线感应电动机 (a) 菱形; (b) 饼式
12.3 直线直流电机
直线直流电机主要有两种类型: 永磁式和电磁式。 前者多用在功率较小的自动记录仪表中, 如记录仪中笔的纵横走向的驱动, 摄影机中快门和光圈的操作机构, 电表试验中探测头, 电梯门控制器的驱动等, 而后者则用在驱动功率较大的机构。
图12 – 8 框架式永磁直线电机
12.5 直线和平面步进电动机
图12 - 12 四相反应式直线步进电动机 图12 – 13 五相反应式直线步进电动机
图 12 - 14 永磁直线步进电动机工作原理
微纳科技20m长直线电机
(The linear motor car experiment vehicles MLX01-01 of Central Japan Railway Company. A photograph is taken in front of 1 JR Central superconductivity linear hall of the pavilion in the 2005 Expo Aichi Japan Nagakute. Photo by Gnsin {{GFDL})
Slotted Linear Motor
(1) Casting (2) Coil (3) Motor Connection
(4) Laminated Core (Iron) (5) Magnet Base (6) Magnets
Switched reluctance linear motor
Synchronous linear motor
Linear Motor Basics
作者:Jack Barrett, Tim Harned, Jim Monnich
Linear Motors Complement Today's Linear Motion Technologies.
Today's linear motion applications are more demanding than ever before. Faster throughput, more exact positioning, longer life, less maintenance, fewer moving parts, the list is never ending. Motion control companies strive to meet and exceed these requirements by continual technological advancement.
Less than a decade ago, it was a difficult task to find a commercially available linear bearing that could travel 5 meters per second with straightness, load capacity and stiffness. Today there are many linear bearings with these attributes and they are fairly cost effective.
Advancements in linear encoder technology allow higher speed operation too. Today's linear encoders and other devices are able to meet this challenge, are less noise susceptible, and cost less.
So with two of the three primary linear motion elements rising to the high speed, high accuracy challenge, the limiting factor is the drive drain.
Photo of today's high precision high speed linear motion technologies: Linear Guide bearings with Speeds to 5 meters per second and load capacity of
thousands of pounds.
Non-contact linear encoders with sub micron resolution and speeds to 3 meters per second.
Improvements in linear, mechanical drives have also moved forward. Ball screw's with higher accuracy, and faster lead's result in higher throughput. Timing belts have high repeatability and speeds of well over 5 meters per second. Both of these technologies have historically solved motion control applications, and will continue to do so. However, neither of these provide the speed and accuracy combination required by an increasing number of today's motion applications.
More and more we face the HIGH ACCURACY, HIGH SPEED APPLICATION. To solve this, the drive train must be able to respond faster, have less wear and have extremely high resolution capabilities. A device that can provide this does exist! It is the Brushless linear motor.
The Linear Motor Concept:
The idea is simple enough. Take a conventional rotary servo motor and unwrap it. So now what was the stator is now a forcer and the rotor becomes a coil or magnet rail. With this design, the load is connected directly to the motor. Direct linear motion is achieved without any rotary to linear transmission devices.
Linear motor technology is not new. Step motor and brushed linear motor products have been available for quite some time. Brushless technology is becoming increasingly popular as applications take advantage of its technology.
Brushed linear had the coils in the linear rail and the magnets were in the forcer. Commutation was accomplished by a linear
commutation bar that ran the length of the motor with brushes in the forcer. This method was both expensive and limited. The cost of winding feet after feet of linear motor rail was time and material intensive. High speed operation was limited due to commutation bar and brushes.
Linear step motors have both windings and permanent magnets within the forcer. It travels along a rail having an etched tooth structure. While maintaining the step motor advantage of open loop operation, the technology does have some limitation in speed and available force.
With brushless servo motor technology, and the supporting electronics to drive them, the above limitations have been eliminated. The forcer is now a set of windings while the stator is a rail of magnets. Commutation is done electronically either by Halleffect sensors or sinusoidal. Hall effect sensors located within the forcer are activated by the magnets on the rail. The amplifier translates these signals into appropriate phase currents. Sine commutation is accomplished using the linear encoder signals back to the controller. A common technique is the use of Hall-effect initially and then switching to
sinusoidal commutation. In any case, the speed of commutation is not the limiting factor. The force generated by the same size motor is greater than brush motor technology due to improved magnet materials.
Linear Motor Benefits:
· High speeds, The maximum speed of a linear motor is limited only by the bus voltage and the speed of the control electronics. Typical speeds for linear motors are 3 meters per second with 1 micron resolution and over 5 meters per second, 200ips, with coarser resolution.
· High Precision: The accuracy, resolution, and repeatability of a linear motor driven device is controlled by the feed back device. With the wide range of linear feedback devices available, resolution and accuracy are primarily limited to budget and control system bandwidth.
· Fast Response: The response rate of a linear motor driven device can be over 100 times that of a mechanical transmission. This means faster accelerations and settling times, thus more throughput.
· Stiffness: Because there is no mechanical linkage, increasing the stiffness is simply a matter of gain and current. The spring rate of a linear motor driven system can be many times that of a ball screw driven device. However it must be noted that this is limited by the motors peak force, the current available and the resolution of the feedback.
· Zero Backlash: Without mechanical transmission components, there is no backlash. Resolution considerations do exist. That is the linear motor must be displaced by 1 feedback count before it will begin to correct its position.
· Maintenance Free Operation: Because the linear motors of today have no contacting parts there is no wear.
What are the Down Sides?
· Cost: Linear Motors are expensive. This is due to the relative low volume produced, and the price of magnets. Since most linear motor designs mount rare earth magnets to the length of the rail, and the cost of these magnets is high, long travel motors become expensive. However as the popularity of linear motors continues, volume will rise and cost will decline. This process has begun. Linear feedback must also be considered in the cost of using a linear motor. Rotary motor feedback, (encoder or resolver) is relatively inexpensive (<$100 list) and is not “length” dependent. Linear motors typically
require a linear encoder for feedback. These devices are many times more expensive than their rotary counterparts. A 100 mm travel linear encoder list in the neighborhood of $500, and cost increases with length. With newer reflective type encoder technologies, the manufacturing costs are declining, and with continued increases in the use of these encoders, prices will follow. Most importantly, if system accuracy requires linear encoder feedback, the cost differential between linear and rotary technology is greatly reduced.
· Higher Bandwidth Drives and Controls: Since there is no mechanical reduction between the motor and the load, servo response, bandwidth, must be faster. This includes higher encoder bandwidth and servo update rates.
· Force Per Package Size: Linear motors are not compact force generators compared to a rotary motor with a transmission offering mechanical advantage. For example to produce even 65 N (15 lb) of continuous force, a linear motor's cross section is approximately 50 mm x 40 mm (2”x 1.5”). Compare this to the cross section of a 10 mm (3/8”) diameter ball screw which produces 100 lb. of thrust and one can see that linear motors are not brute force devices.
· Heating: In most linear motor applications, the forcer is attached to the load. Any I2R losses are then directly coupled to the load. If an application is sensitive to heat, thermal management techniques need to be applied. Air and water cooling options are popular and common.
· No (minimal) Friction: This may not sound like a problem, but it certainly can be. For instance, a linear motor is traveling at 3 meters/second (120 ips) and loses power.
Without some resistance in the system, it does not take long before the motor reaches the end of stroke and mechanical stops.
Choosing a linear motor:
Choosing the right linear motor for an application is not a simple task. Selecting the right technology for the application, force calculations, thermal considerations, bearing loading, commutation methods, etc., must be considered. Within this article,
technology will be discussed, not sizing solutions.
However, knowing the basic types and the associated advantages and disadvantages will assist in the end solution. Three technologies of brushless motors are discussed. They are; ironcore, aircore (ironless), and slotless.
IronCore Linear Motor
Construction:
This motor takes its design straight from a brushless rotary motor. As shown in fig.1, the motor consists of a flat iron rail to which rare earth permanent magnets are bonded. The Forcer is constructed of laminations and coil's wound around the “teeth” of the laminations. Thermal sensors are mounted internal to the windings, sensing temperature. Hall effect sensors are either mounted in the coil area or mounted on the edge of the motor. These sensors are activated by the magnets on the rail and used for commutation of the windings.
Advantages:
· Highest Force per Size: Utilizing laminations to concentrate the flux field, this type of motor produces the greatest force per package size.
· Lower Cost / Lower Weight Rail: The next type of motor we will examine is the AirCore motor. This design uses two sets of magnet rails. Since the magnets are expensive, these motors are more expensive than the IronCore design. Additionally, the magnet rail is heavy and when working with multi-axis systems, or if the motor is configured that the rail is moving, the double set of magnets can be a serious performance limitation.
· Good Heat Dissipation: Since the windings are wound around an iron lamination, heat dissipation is excellent. Additionally, cooling tubes can be routed through the laminations. These tubes can then have air or liquid forced through them, improving thermal management.
Disadvantages:
· Normal Attractive Force: Since the forcer is primarily made of iron, and the gap between the forcer and the winding is normally only 0.8 mm (0.030”) there is a very strong attractive force between the forcer and the rail. This force can be as much as 10 times the continuous thrust force of the motor. If a motor has 100 lb. of continuous force, it may have as much as 1000 lb. of normal force pulling it toward the magnet rail. This normal force must be taken into consideration when sizing linear bearings.
· Cogging: Since the forcer is made of iron and it passes over magnets, there is a variation in the thrust force as it passes each magnet. This is referred to as cogging and affects low speed smoothness (velocity ripple). The design of the linear motor is optimized to minimize cogging by skewing magnets and by other techniques.
AirCore Linear Motor
Construction:
This design is referred to as AirCore or Ironless. Two magnet rails oppose each other, north and south, as shown in figure 2. A spacer bar between them keeps the two sides from closing together.
The forcer is constructed of coils wound and held together with epoxy. This winding assembly is then topped off with an aluminum bar. This bar is used for mounting the load and also for heat removal. The Winding itself has no iron in it, thus the names “AirCore” or “Ironless.\" As with the IronCore, thermal sensors and hall effect sensors are mounted to the Forcer.
Advantages:
· No Attractive Forces: Because the forcer contains no iron, there exist no attractive forces between the forcer and the rails. This means no additional forces on bearings. The motor is easier to handle and install without these attractive forces.
· No Cogging: With its ironless forcer, this style motor has no cogging. This is ideal in applications requiring extreme velocity control. This type of motor is normally used in conjunction with air bearings due to the air-bearing's “frictionless” / ultra smooth characteristics.
· Low Weight Forcer: These forcers have low weight. In applications that have very light payloads, this can be a benefit. Higher acceleration / deceleration may be possible due to this lower weight, which of course results in higher throughput.
Disadvantages:
· Heat Dissipation: Since the forcer is made of wound coils and held together with epoxy, the heat must leave the coils by traveling up the coil to the aluminum mount plate and out to a heat-sink. Heat also passes through the air gap and into the magnet rail. Both of these paths have high thermal resistance's and thus make thermal management of the motor difficult.
· Structural Stiffness: The forcer is made of coils and epoxy. The force is generated at the coil. This means that all of the exerted force is on the windings and epoxy. This is a weak structure as compared to the IronCore. This weakness limits the maximum sizes and forces to which these types of motors can be manufactured without additional structural members being added.
· Force per Package Size: Due to the thermal and structural limitations, the force per package size of this type of motor is low. In addition, the double rail design, also takes up additional space.
Slotless Linear Motor
Construction:
The rail is the same as those used for the IronCore design. Simply a flat iron plate with magnets bonded to it.
The Forcer is unique. It begins with a coil similar to those used in the AirCore. A \"backiron\" plate is placed behind the coil. This assembly is placed inside an aluminum housing with an open bottom.
The housing is then filled with epoxy, securing the winding and back-iron into the housing. Thermal sensors are internal.
Slotless Linear Motor
Advantages / Disadvantages:
Since the Slotless Design is a hybrid between the IronCore and the AirCore, the advantages and disadvantages are really comparisons between theses two types.
· Lower Cost Magnet Rail: Since the same type of magnet rail is used as the IronCore (single row), this design also has a low cost magnet rail compared to the AirCore.
· Lower Weight Magnet Rail: As a single magnet rail is employed, the weight is less then half that of the AirCore. This means less load and higher throughput in multi-axis systems.
· Structurally Strong Forcer: With the body of the forcer being made of aluminum and the windings being bonded to this housing, the strength of the forcer is much greater than that of the AirCore. Thus reducing the possibility of motor fatigue contributed failures.
· Light Weight Forcer: Although not as light as the AirCore, the slotless design is much lighter than its equivalent IronCore. This results in higher throughput in light load applications.
· Lower Attractive Forces: The Slotless design has a back-iron causing attractive forces between the forcer and the rail. This attractive force is significantly less than that of the IronCore, on the order of five or seven times the continuous force. · Lower Cogging: With the larger magnetic gap between the magnets and forcer backiron, the slotless design has lower cogging. This enables the Slotless Design to operate in applications requiring good velocity control.
· Heat Dissipation: The Slotless design, with the coil resting across the backiron, which is in direct contact with the aluminum housing, has very good heat transfer and is easy to manage.
· Force per package size: The force per package size of this design is between the Aircore and the IronCore. Since the Slotless Design has a very good thermal path it is capable of handling higher currents than the AirCore design and thus generates higher forces.
Summary Chart:
Below is a summary of linear motor attributes and how each type of motor compares to the others.