Introduction

Compact, rugged and easy to use. Just aim MODEL: AR320

Non-contact infrared thermometer Instruction manualVersion number: SZ320-1-00

4. Emissivity: Most organic materials and painted or oxidized surfaces have an emissivity of 0.95 (pre-set in the unit). Inaccurate readings will result from

measuring shiny or polished metal surface. To compensate, cover the surface to be measured with masking tape or flat black paint. Measure the tape or painted surface when the tape or painted surface reach the same temperature as the material underneath.

Quick start instruction

BCDEAFTrigger5Battery doorfinger indentsG(Figure1)(Figure2)1. Press battery door clip, install battery correctly. Pull the trigger, LCD display reading& battery icon. Release the trigger and the reading will hold for 7 second.LCD display: A data hold icon B scanning icon C laser on icon D back light on icon E battery power icon F measuring unit G measuring reading 2. Locating a hot spot: To find a hot spot aim the thermometer outside the area of interest, then scan across with up and down motions until you locate the hot spot.(please turn on the laser for accurate measuring)

and push the button, read current surface temperature in less than a second. Safely measure surface temperature of hot,

hazardous or hard-to-reach objects without contact.

Warning Do not point laser directly at eye or in-directly off reflective surface.

1. When taking measurement, points thermometer toward the object to be

measured and hold the yellow trigger. the How it works object under measuring should be larger Infrared thermometer measure the surface than the spot size calculated by the field temperature of an object. The units optical of view diagram.

system sense the object,s emitted energy 2. Distance & spot size: As the distance from with different wavelength. It is collected and the object increase, the spot size of focus onto a detector. The unit,s electronics measuring area becomes larger.

system translated the information into a D:S=12:138mm@75mm@132mm@300mm900mm1500mm temperature reading which is displayed on the unit.Cautions

Infrared thermometer should be protected 1.5\"@3.0\"@5.3\"@12\"36\"60\" from the following:

--EMF (electro-magnetic fields) from welders, induction heaters.

--Thermal shock (cause by large or abrupt 3. Field of view: Make sure the target is larger ambient temperature changes allow 30 than the unit's spot size. The smaller the minutes for unit to stabilize before use). target, the closer the measure distance. --Do not leave the unit on or near objects of When accuracy is critical, make sure the high temperature. target is at least twice as large as the spot size.

Red laser point Maintenance

1) Lens cleaning: Blow off lose particles using clean compressed air. Gentlydetection hole brush remaining debris away with a moist cotton cloth.

2) Case cleaning: Clean the case with a damp sponge/cloth .

(Figure 3)Attention:Note:

Red laser point only position the general 1) Do not use solvent to clean lens.direction, the detection hole is the main parts 2) Do not submerge the unit in water.

measure the temperature

SpecificationsTemperature range -32 to 320 ℃ (-26 to 608℉)5-32℃(-26℉) to 0℃(32℉) ±3℃ Accuracy 0℃(32℉)to 100℃(212℉) ±2℃(In the condition of)100℃ hereinbefore ±2℃or±2% 1 23℃±3℃2 whichever is greater46Repeatability 1% of reading or 0.1℃ 3Response time500 mSec, 95% response(Figure4)(Figure5)Spectral response8-14 um4. Diagram description

Emissivity pre-set 0.95(1)Trigger: When pulling the trigger,Ambient operating range0 to 40℃ (32 to 104℉)10-95% RH noncondensing, @ upto 30℃ (86℉) LCD display reading with SCAN icon.Relative humidityStorage temperature-20 to 60℃ (-4 to 140℉) without battery Release the trigger, display readingWeight/Dimensions130g ;146*80*38mm with HOLD icon for 7 sec(approx). Power2 x AAA battery Built-in 20 sec auto power off function.(2)Laser on/off button

Battery life (Alkaline)Laser Models:12 hrs(3)Celsius / Fahrenheit switch buttonDistance to Spot Size12:1(4)Back light on/off button:When back light is on, any operations will keep back light for 10 sec. (5)LCD

(6)Battery door: When replace battery door, please pull the battery door.